Heliport Lighting Solutions
Flashes for Heliports
It is recommended that a helistation light be installed when long-range visual guidance is deemed necessary and is not provided by other visual means, or when it is difficult to identify the helistation due to surrounding lights.
The Helistation Device FLASHELEK meets the requirements of theICAO (Chapter 14) and FAA.
Our products
Device JX4300
The JX 4300 helistation light is designed to indicate to pilots the presence of a helistation base, especially when the light environment is heavily polluted. Typical applications are Helipads for hospitals, firefighters, gendarmerie, etc.
- Management via a current loop
- Remote control
Flashing light head
The FLASHELEK xenon lamp is specially developed to cover a 360° azimuth
as well as the elevation corresponding to ICAO requirements.
- Flash lamp PAR56
- Power 2000V
Device JX4360
The JX 2360 is remotely controlled either by simple dry contacts or by an RS485 (J-Bus) bus. A JX5600 Monitor Controller has been developed to manage the JX2360 Flashs from the tower and service operators via a UDP connection to the site’s controllers as well as an intranet server.
- Management via UDP connection
- Remote control
Technical information
Energy by flash
4 x 40 J
Maximum intensity in white
20 000 cd
Flash period
2 SEC
Optional gloss selection
100% (day), 20% (night)
Brightness switching
Dry contact
Alarm forwarding
A relay close when the alarm occurs.
Operating voltage
230 V AC 50/60 Hz +/- 10% (110V AC 60 Hz on request)
Energy consumption
less than 200 W
Power factor
better than 0.95
Ambient operating temperature
-25 °C to + 55 °C ( drying resistance optional can be installed when the relative humidity is particularly high or the outside temperature is particularly low).
IP 66 protection rating
Exterior dimensions
400 mm x 300 mm x 160 mm
Weight of the control cabinet
11 kg
Weight of the fire head
7 kg
Additional information
The device comes with a 5 m long fire cable, a 5 m long remote control cable and a 2 m long power cable.
One photocell optional can be connected to switch the brightness automatically.
Electronic cards JX4300
Auxiliary Panel 401301, 301301 ou 300403
Clock Panel 401164, 301164
Power Panel 401201, 301201 ou 300408
Download the documents - Technical Documentation
French
Documentation in French version
English
Documentation in English version