Airports Lighting Solutions
Airfield Lighting Solutions
Our flash systems allow the installation of "Sequential Flash Lamp Systems". (SFLS) Category I, II and IIII with or without "Threshold Identification Lamp (REILS)approach systems with Omni-directional lamps (ODALS) and "Heliport Approach Systems".
FLASHELEK flash systems comply with the FAA and Annex 14 of the ICAO RecommendationsThey are also approved by the French STNA. These two families of devices use the same xenon flash lamp, in PAR56 format, marketed worldwide by many distributors.
Our products
JX2300 Box
The JX 2300 is remotely controlled with a 24V or 48V DC voltage and is controlled by pulses on a 4/20 mA current loop. A JX5300 Monitor Controller has been developed to manage the JX2300 Flashs from the tower via a current loop.
- Management via a current loop
- Remote control
Firehead FT34
The F34 light head is equipped with a 2000V PAR56 Flash lamp (product photo not contractual)
- Flash lamp PAR56
- Power 2000V
JX2360 Box
The JX 2360 is remotely controlled either by simple dry contacts or by an RS485 (J-Bus) bus. A JX5600 Monitor Controller has been developed to manage the JX2360 Flashs from the tower and service operators via a UDP connection to the site’s controllers as well as an intranet server.
- Management via UDP connection
- Remote control
Description of SFLS
Sequential Systems of Flash Lamps SFLS) can be implemented in different ways, depending on ICAO recommendations:
Category I SFLS, without REILS
30 flashes operate at a distance of 14 ms and at a period of 0.5 s.
SFLS Class I with REILS
This is the same configuration to which a REILS at the runway threshold.
SFLS Category II or III without REILS
21 flashes operate at a distance of 14 ms and at a period of 0.5 s.
SFLS Category II or III with REILS
This is the same configuration to which a REILS at the runway threshold.
REILS Alone
The REILS is a set of two lamps that flash simultaneously. When one of them stops, the second one also stops thanks to the safety mode
ODALS
5 flashes plus a REILS run at a 267 ms interval (or 8 flashes or more at a 67 ms interval) and a period of 2 s. (or1 s.)
Approach of Heliports
4 flashes work at a distance of 267 ms and at a period of 2 s.
JX5600 Control Tower Control Panel
Flash period setting capability
0.5 s, 1s, 1.5 s or 2 s
Inter flash delay setting capability
14 ms, 67 ms, 267 ms
Preventive maintenance
Individual flash counter on each lamp.
Shine selection
100% (day), 10% (dusk), 3% (night)
Brightness switching
Digital control via RS485 line (J-Bus) / Dry contacts on simple systems.
Alarm forwarding
in the RS485 line. The processing of this information is available on a
port 5556 to an Automate
Operating voltage
230 V AC 50/60 Hz +/- 10% (110V AC 60 Hz on request)
Energy consumption
less than 100 W
Operating temperature
0 °C to + 55 °C | 19 " 1U standard rack
Weight
2 kg
Electronic cards JX2300
Auxiliary Panel 401002, 301002 ou 309403
Clock Panel 401103, 301103 ou 300209
Auxiliary Panel 401002, 301002 ou 309403
Electronic cards JX2360
Auxiliary Panel 400702, 300702
Power Panel 400704, 300704
Clock Panel 401364, 301364
Download the documents - Technical Documentation
French
Documentation in French version
JX2300 - Boucle de courant
JX5300 - Moniteur de contrôle
Boucle de courant
Manuel utilisateur
Technical information
English
Documentation in English version